NOTE:
if the room thermostat is set to a temperature below the air temperature, the unit will not
heat. In this case, turn the thermostat knob to a higher temperature.
SUMMER VENTILATION
To use the unit as a fan, set the power switch on the ventilation-only position.
TURN OFF (FANSTOP 3.3 Kw Models)
-
Turn the power switch to (fan) position
for about 2 minutes to allow the device to cool
down.
-
Turn the power switch to O (OFF) to stop the unit completely.
WARNING
NEVER UNPLUG TO STOP THE UNIT.
DANGER OF OVERHEATING!
SAFETY THERMOSTAT - RESET
CAUTION: BEFORE PERFORMING THE OPERATIONS DESCRIBED BELOW TURN THE POWER OFF,
DISCONNECT FROM THE POWER SOURCE AND MAKE SURE IT IS COMPLETELY COOLED
The unit is equipped with a safety thermostat that kicks in and shuts the unit off to keep it from
overheating. If this happens:
Find and eliminate the cause of the overheating: obstructed sections of venting, air
temperature too high, etc.
Turn off the power and let it cool for a few minutes
To reset the thermostat, press the RESET button ALL THE WAY DOWN, located on the control
panel, using a pointed tool.
If the unit does not restart, or the safety thermostat continues to intervene, turn it off and
contact qualified trained personnel for service.