Manufacturer of high quality equipment for powder coating
_________________________________________________________________
43
Troubleshooting guide
General information
Fault
Criteria
Solution
H11 (error message on
Gun not connected
Connect the gun
control unit)
Gun plug or gun cable
Replace corresponding
defective
part or send in for repair
Remote control on pow-
Replace remote control
der gun defective
(gun cap)
Gun LED remains
High voltage adjustment
Increase high voltage
dark, although the gun
is set too low
is triggered
Gun plug or gun cable
Replace defective part
defective
or send in for repair
LED on gun defective
Replace gun back cover
Powder does not ad-
High voltage and current
Check the high voltage
here to object, al-
deactivated
and current setting
though the gun is trig-
High voltage cascade
Send in the gun for re-
gered and sprays
defective
pair
powder
Objects are not properly
Check the grounding
grounded
Fault
Causes
Fault elimination
The gun does not
Compressed air not pre-
Connect the equipment
spray powder, al-
sent
to the compressed air
though the control unit
Too little conveying air
Increase the powder
is switched on and the
output and/or total air
gun is triggered
volume on the control
unit
Injector or nozzle on the
Clean corresponding
injector, powder hose or
part
powder gun clogged
Insert sleeve in the in-
Replace or insert
jector worn or not in-
serted
Nozzle in the injector
Replace
clogged
Fluidizing not running
(see above)
No conveying air:
Motor throttle defective
Replace the motor throt-
tle
Solenoid valve defective
Replace the solenoid
valve
Front plate defective
Send in for repair