Manufacturer of high quality equipment for powder coating
______________________________________________________
19
Initial start-up
Setting the device type
Adjust the corresponding device type (fluidizing, box or stirrer device)
by pressing the key
T16
.
Note:
If the control unit is supplied as a component of an com-plete unit,
then the corresponding system parameter is set correctly by the
factory!
Manual devices are subdivided into fluidizing, box or stirrer types. These
types differ in the control of the vibrator output and the behavior of the
flu-idizing air.
Device type
AUX output function
Fluidizing air function
Fluidizing device
Always
Off
(no vibration)
Fluidizing air is controlled
(PROTON )
by two different methods:
Turning on the fluidization
key
T16
will feed air to the
hopper until key is turned
off
Triggering the gun is turn-
ing on the fluidization too,
fluidization can be turned
off with key
T16
Box device
Vibration
On
during trig-
Fluidizing air is switched
(PROTON II)
gering, delay of 1 minute
On
parallel by the trigger.
after releasing gun trigger
It runs after for 1 minute
The key
T16
switches the
The key
T16
switches the
vibration
On
and
Off
fluidization
On
and
Off
parallel to the vibration
Stirrer device
Stirrer
On
when gun trig-
No fluidization, no function
( S)
gered
of key
T16
Manual unit with
Stirrer
On
when gun trig-
Fluidization is switched
fluidization
gered
On
and
Off
with trigger
( S Fd)
The key
T16
switches
Off
the fluidization, it can only
be turned
On
by pressing
the key again
Note:
The system parameter P0 of the manual unit may not be set on
3 (automatic unit)!
A wrong parameterization leads to various malfunctions!
Preparing the powder hopper/container
Prepare the powder hopper or powder box according to manual equip-
ment type (PROTON , B, S, L etc.), reference the operating manual for
the equipment type being used.