Operating modes
The PROTON II Manual gun control unit can be operated with two
operating modes. According to the selected application mode, the spray
voltage and the spray current are automatically adjusted and limited.
Predefined operating mode (Preset mode)
The PROTON II Gun control unit provides three predefined application
modes (flat parts, complicated parts and recoat parts already painted one
time). When operating in this mode, the spray voltage and spray current
are au-tomatically set and limited.
In this operating mode, current (
µA
) and high voltage (
kV
) are preset,
powder and air volume can be adjusted and saved. The powder and
air volume are stored separately for each predefined application mode.
User-defined operating mode (Program mode)
In this operating mode, 20 individually definable programs (P01-P20)
are available. These programs are automatically saved and can be
recalled again as the application requires.
The values for current, high voltage, powder output, total air, electrode
rinsing air and fluidizing air (if available) can be set as needed for a given
application.
Note:
The specified values in the 20 programs and 3 application modes are
saved automatically, without confirmation, after a two second delay
and the display changes from preset values to actual values!