Operating and Maintenance Manual
18 |
P a g e
D e c a p p e r O & M M a n u a l R e v D
3.
The shuttle and spring inside the Decapping Die need to be changed
to the shorter shuttle to allow clearance for the taller rifle cases.
(These are in a bag marked as
“Rifle Spring”).
❖
The pistol shuttle will work for 300BLK and 223 cases but will
have a short spring life. It will NOT work for 308 cases.
❖
Refer to the section in this manual that covers the new rifle
pegset
s, they work really well….
➢
Calibre conversion process
To change calibres, you need to.
1.
Remove any residual cases from the case feeder and from the pegs.
Check the casefeeder is empty by running for a short time and
listening and checking for any cases in the case feeder or feed hose.
2.
Turn off the Decapper and unplug the Decapper power brick from
the wall socket.
3.
If the conversion requires the drop tube to be changed remove the
drop tube by unscrewing the winged bolt securing the drop tube
and replacing it with the required tube.
4.
Check and adjust the drop tube height. Drop 2 cases into the drop
tube and check the extractor groove of the second case is visible,
adjust the height of the drop tube as required. Refer to the
photograph below.