6. CLEANING AND MAINTENANCE
Cut the gas supply.
- Let cool completely the device before any technical intervention or cleaning.
- For cleaning, only use non-abrasive products, clean regularly the external walls of
your device with warm water and wash liquid: avoid the abrasive towelling. Rinse your
device with a wet sponge.
- Never clean the device under a water jet, the infiltrations would risk to damage it in a
irreparable way.
- During a prolonged non-use, we recommend you strongly to keep the device shield-
ed from the humidity .
7. TECHNICAL SPECIFICATIONS
8. GUARANTEE
Conditions of guarantee
The guarantee applicable to any device is the commercial guarantee of the distributor
or the retailer. Please contact the store where you bought your device to know the
precise conditions.
The guarantee grants no right for damages.
The dispositions which follow are not exclusive of the profit of the legal guarantee
planned by articles 1641 and following ones of the Civil code relative to the defects
and the latent defects.
Exclusion clauses of the guarantee
Bad installation and bad maintenance, in particular if they do not respect cur-
rent regulations or instructions appearing in this user guide.
Cannot benefit from the guarantee the repairs required as a result of false operations,
of inappropriate use, of carelessness or of excess loads of the device, as well as
those resulting from defective installations.
8
Model
Outside dimen-
sions
Power
Nb of burners
Weight
GAR 14 XL 600x630x425 mm
14 kW
1 fire 14 kW
30 Kg
A safety thermocouple cuts the gas supply if the burner is extinguished. The low flame
of the appliance is pre-adjusted in the factory, it must not be changed.
5. FUNCTIONING / HANDLING
a) Installation/Assembly:
- Unpack carefully the machine from its packaging.
- Place the device on a plane and heatproof surface in a well ventilated place.
- Never place the device near a wall or near a partition makes of combustible materials
even if it is very well isolated.
- A distance of minimum 10 cm with the partition or the wall is necessary.
- Remove the protective film from the machine.
b) First starting
:
During the first use, warm your machine up outside during about 30 min to evacuate
residual smokes of manufacturing oil from the metallic parts. This may emit a slight
smell for a few moments.
First cleaning
Clean the device before the first use. (See 6 Cleaning)
Gas connection
The appliances run on the following gases: Butane G30, Propane G31, Natural gas
G20/G25. The appliances are originally delivered with a Butane/Propane injector corre-
sponding to the category II2E+3+. The connection is made thanks to a thread 3/8.
The heat release rate of the appliance is
GAR 14 XL
14 kW
For a use in natural gas, change the injectors. They are delivered in a small plastic bag
in the package. Unscrew completely the nut and then the injector inside the hole.
Connect the appliance to the gas supply pipe, interposing a stop valve which enables
the appliance to be insulated from the rest of the installation.
Check the supply pressure using a manometer when all the burners are lit. It must be
equal to the indications on the rating plate.
The fresh air flow required for combustion air supply is:
- GAR 14 XL 25.9 m3/h
5