background image

 

6. CLEANING AND MAINTENANCE 

 
Cut the gas supply. 

 

- Let cool completely the device before any technical intervention or cleaning. 
-  For  cleaning,  only  use  non-abrasive  products,  clean  regularly  the  external  walls  of 
your device with warm water and wash liquid: avoid the abrasive towelling. Rinse your 
device with a wet sponge. 
- Never clean the device under a water jet, the infiltrations would risk to damage it in a 
irreparable way. 
- During a prolonged non-use, we recommend you strongly to keep the device shield-
ed from the humidity . 
 

7. TECHNICAL SPECIFICATIONS 

 
 
 
 
 
 

 
 
8. GUARANTEE 
 
Conditions of guarantee 

 
The guarantee applicable to any device is the commercial guarantee of the distributor 
or  the  retailer.  Please  contact  the  store  where  you  bought  your  device  to  know  the 
precise conditions. 
 
The guarantee grants no right for damages. 
 
The  dispositions  which  follow  are  not  exclusive  of  the  profit  of  the  legal  guarantee 
planned  by  articles  1641  and  following  ones  of  the  Civil  code  relative  to  the  defects 
and the latent defects. 
 

Exclusion clauses of the guarantee 

 

Bad  installation  and  bad  maintenance,  in  particular  if  they  do  not  respect  cur-
rent regulations or instructions appearing in this user guide.  
 

Cannot benefit from the guarantee the repairs required as a result of false operations, 
of  inappropriate  use,  of  carelessness  or  of  excess  loads  of  the  device,  as  well  as 
those resulting from defective installations. 
 

Model

 

Outside dimen-

sions 

Power 

Nb of burners 

Weight 

GAR 14 XL  600x630x425 mm 

14 kW 

1 fire 14 kW 

30 Kg 

A safety thermocouple cuts the gas supply if the burner is extinguished. The low flame 
of the appliance is pre-adjusted in the factory, it must not be changed.  

 
5. FUNCTIONING / HANDLING 

  

a) Installation/Assembly: 
 

- Unpack carefully the machine from its packaging. 
- Place the device on a plane and heatproof surface in a well ventilated place. 
- Never place the device near a wall or near a partition makes of combustible materials 
even if it is very well isolated. 
- A distance of minimum 10 cm with the partition or the wall is necessary. 
- Remove the protective film from the machine. 
 

b) First starting

 

During  the  first  use,  warm  your  machine  up  outside  during  about  30  min  to  evacuate 
residual  smokes  of  manufacturing  oil  from  the  metallic  parts.  This  may  emit  a  slight 
smell for a few moments. 

 

First cleaning 
 

Clean the device before the first use. (See 6 Cleaning)  
 

Gas connection 

 
The  appliances  run  on  the  following  gases:  Butane  G30,  Propane  G31,  Natural  gas 
G20/G25. The appliances are originally delivered with a Butane/Propane injector corre-
sponding to the category II2E+3+. The connection is made thanks to a thread 3/8.  

 

The heat release rate of the appliance is   

GAR 14 XL   

14 kW 

 
For a use in natural gas, change the injectors. They are delivered in a small plastic bag 
in the package. Unscrew completely the nut and then the injector inside the hole. 
 
Connect the appliance to the gas supply pipe, interposing a stop valve which enables 
the appliance to be insulated from the rest of the installation.  

 

Check the supply pressure using a manometer when all the burners are lit. It must be 
equal to the indications on the rating plate. 

 

The fresh air flow required for combustion air supply is: 
 
- GAR 14 XL                 25.9 m3/h 
 

Reviews: