rollease acmeda AUTOMATE AU Manual Download Page 10

10 

| Automate

 Programming Instructions | FT Tubular Motors 

ROLLEASE ACMEDA

SEC

SEC

S

S

5

5

Hold 

UP

 and 

STOP 

on 

controller.

Hold 

DOWN

 and 

STOP 

on controller.

Move shade to the desired 

lowest position by pressing 

the 

DOWN

 button.

Move shade to the desired 

highest position by pressing 

the 

UP

 button.

To save upper limit, hold 

UP

 

and 

STOP

.

To save lower limit, hold 

DOWN

 and 

STOP

.

Approx.

Approx.

Motor Response

Motor Response

Motor Response

Motor Response

ADJUSTING LIMITS

SEC

SEC

S

S

5

5

Approx.

Approx.

IMPORTANT (ULTRA-LOCK V2 ONLY)

When using the Ultra-lock V2, the bottom limit must be set within the ‘locking zone’. Jog the weightbar down until you hear both locking pins 
click into each latch housing.

5.2  Adjust lower limit

5.1  Adjust upper limit

Summary of Contents for AUTOMATE AU

Page 1: ...pacity of an AC motor for larger shade applications Three alternate modes of operation include E type for standard use MANUAL FT Mode for use with conventional locking devices with fabric tensioning A...

Page 2: ...S AND CHANNELS 11 6 1 Using motor P1 Button to add a new controller or channel 11 6 2 Using a pre existing controller to add or delete a controller or channel 11 7 FAVORITE POSITIONING 12 7 1 Set a fa...

Page 3: ...e is compatible with end application Do not expose the motor to water or install in humid or damp environments Motor is to be installed in horizontal application only Do not drill into motor body The...

Page 4: ...gning key way in crown and drive wheel into the tube Step 5 Mount motorized tube onto brackets Refer to Rollease Acmeda System Assembly Manual for recommended crown drive and bracket adapter kits 1 AS...

Page 5: ...connecting or disconnecting this motor This connector must not be acces sible to the end user It shall be placed within a pelmet box or within a housing in accordance to AS NZS 60335 1 2011 or BS EN...

Page 6: ...limit TENSION UNLOCK MODE 1 E Type DEFAULT MODE 2 FT MODE Automatic Lock MODE 3 FT MODE Manual Lock 2 62 x TUBE DIAMETER 2 62 x TUBE DIAMETER Inactive zone of impact detection Active zone of impact d...

Page 7: ...UNCTIONS P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described Short Press If limit is NOT set None No Action None No Action If limits are set Operational control of...

Page 8: ...uring initial set up Hold P1 button on motor head To check travel direction of shade press UP or DOWN on controller Quick Press Step Long Press Continuous Travel To reverse shade direction hold both U...

Page 9: ...s set refer to Section 10 to activate Fabric Tension Mode After setting limits motor will automatically exit from initial set up mode Move shade to the desired highest position by pressing the UP butt...

Page 10: ...pressing the UP button To save upper limit hold UP and STOP To save lower limit hold DOWN and STOP Approx Approx Motor Response Motor Response Motor Response Motor Response 5 ADJUSTING LIMITS SEC SEC...

Page 11: ...ntroller to remove it Hold P1 button on motor head Hold STOP on controller to add Motor keeps original limits Approx Approx Motor Response Motor Response Motor Response Motor Response Motor Response 6...

Page 12: ...the desired position by pressing the UP or DOWN button on the controller Press P2 on controller Press STOP on controller Press STOP on controller Approx Motor Response Motor Response Motor Response Mo...

Page 13: ...hen re power the motor The Impact Detection feature only works in the active zone during downward movement see Section 2 4 All three modes have this impact detection feature deactivated by default see...

Page 14: ...s selected Note Motor must be in FT mode before switching between lock modes Press P2 on controller Press UP on controller Press STOP on controller Press DOWN on controller Press UP on controller FT M...

Page 15: ...otor Response Shade moves DOWN to the bottom limit then pauses Shade moves UP to engage the locking device Motor Response Motor Response Motor Response Shade moves DOWN and UP to engage the Ultra Lock...

Page 16: ...CONTROLLER Motor Response PRESS UP ON CONTROLLER Motor Response BEEP x3 JOG x3 Motor Response Activated PRESS STOP ON CONTROLLER Motor Response Deactivated ON REMOTE ON SENSOR PRESS P2 ON CONTROLLER M...

Page 17: ...ce is to far from transmitter Move transmitter to a closer position Power failure Check power supply to motor is connected and active Incorrect wiring Check that wiring is connected correctly refer to...

Page 18: ...18 Automate Programming Instructions FT Tubular Motors ROLLEASE ACMEDA G 13 NOTES...

Page 19: ...19 Automate Programming Instructions FT Tubular Motors ROLLEASE ACMEDA 13 NOTES...