142
6
FA
Q
An Error Message Appears
This describes the error messages that may appear on the machine's display and how to take
action to remedy the problem. If the action described here does not correct the problem or if an
error message not described here appears, contact your authorized Roland DG Corp. dealer.
[CLOSE COVER (FRONT COVER/COVER L/COVER R)]
Close the front, left, and right covers. For safety, the print-head carriage does not operate while a cover is open.
If the message does not disappear even after you close the front cover, the media may be in contact with
the front cover, which will prevent the front cover from closing. In this situation, try the following methods.
Close the front cover while holding down the end of the media.
Pull the media to the front until it is in a position where its end is not in contact with the front cover, and
then close the front cover.
Cut the end of the media so that it is not in contact with the front cover, and then close the front cover.
If the media is still in contact with the front cover even after you try these methods, change the media.
[CAN'T PRINT CROP CONTINUE?]
The size of the data including the crop marks is larger than the printing or cutting area of
the loaded media.
To continue printing without correcting this, press
. At this time, the portion extending beyond the
printing area and the crop marks are not printed. To stop printing, stop sending data from the computer, and
then raise the loading lever. Make the printing area wider, for example, by replacing the media with a larger
piece of media, and then send the data again.
The size of the data being printed is too small.
Make the scanning-direction size of the data at least 65 mm (2.6 in). To continue printing without correcting
this, press
. At this time, the data is output without printing the crop marks. To stop printing, stop
sending data from the computer, and then raise the loading lever. Change the size of the data, and then send
the data again.
[TEMPERATURE IS TOO HIGH **°C]
The temperature of the location where the machine is installed has risen above the ambient
temperature at which the machine can operate.
Operation cannot be continued. Switch off the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the temperature of the installed location to a temperature at
which operation is possible (18 to 25°C (64 to 77°F)), allow the machine to come to room temperature, and
then turn on the power.
[TEMPERATURE IS TOO LOW **°C]
The temperature of the location where the machine is installed has fallen below the ambient
temperature at which the machine can operate.
Operation cannot be continued. Switch off the sub power. The displayed temperature is the current ambient
temperature of the installation location. Bring the temperature of the installed location to a temperature at
which operation is possible (18 to 25°C (64 to 77°F)), allow the machine to come to room temperature, and
then turn on the power.
[HEATING TIMEOUT CONTINUE?]
The dryer did not reach the preset temperature.
This occurs because the temperature of the location where the machine is installed is too low. We recommend