Using the Dryer
4
Advanced
Functions
99
Description
With the default settings, simply switching on the power does not make the dryer warm up to the set tem-
perature. The temperature rises to the set temperature when the media is loaded correctly and
lights. You can also make this setting in the software RIP. When you have made the setting in the software RIP,
the software RIP's setting is used.
* Depending on the usage environment, the temperature of the dryer may become higher than the set
temperature, but this does not represent a problem.
Default Setting
[DRYER]: 40°C (104°F)
Dryer Control While Idling
Note: Preheating: State in which the main power and the sub power are switched on and
is not lit
(state in which the media setup is not completed)
Procedure
Hold down
and press
.
Press
, then
to display the screen shown
on the left.
Press
.
Press
or
to select a setting.
Press
to confirm your entry.
MENU
The system performs heating to the set temperature at all times, without lowering
the temperature during preheating.
30°C(86°F)
The system maintains a temperature of 30°C (86°F) during preheating.
OFF
The dryer turns off while idling.
Press
, then
to go back to the original screen.
Default Setting
[PREHEATING]: 30°C (86°F),
HEATER MENU
PREHEATING
PREHEATING
30゜C MENU