66
Chapter 4. Effect Settings
1.
Press the [MASTER COMP/EQ] button.
The [MASTER COMP/EQ] button lights.
fig.04-011-mastercomp.eps_70
2.
Use the [F2], [F3], or [CURSOR] buttons to select the
parameter.
3.
Use the [-] [+] buttons or the [VALUE] dial to adjust
the setting.
The sound may be distorted in a certain setting.
You can choose whether the master compressor/
equalizer settings will be independent for each kit, or be
In the “F2 (M COMP)” screen, the “Gain Reduction Meter” and
the “Output Meter” are displayed.
The “gain reduction meter” shows the change in level (dB)
produced by the master compressor.
The “output meter” shows the output level following the
master compressor and EQ.
Adjust the master compressor’s “Gain” so that the output
meter does not exceed 0 dB (i.e., so that it does not clip).
fig.04-012-mastercomp.eps_70
The output meter shows only the level of the output
signal from the MASTER OUT jacks and DIGITAL OUT
jack. It does not show the level of the output signal from
the PHONES jack or the DIRECT OUT jacks.
Here’s how to restore the master compressor settings to the
default state (an appropriate amount of effect). For details on
the actual values, refer to the “Master compressor setting
examples” below.
1.
Press the [MASTER COMP/EQ] button.
The [MASTER COMP/EQ] button will light.
2.
Press the [F5 (DEFAULT)] button.
A confirmation screen will appear.
3.
Press the [F5 (EXECUTE)] button to execute.
In the “M EQ” screen, pressing the [F5 (DEFAULT)]
button will set the master EQ “Gain” to “0.”
Editing the Master Comp/EQ Settings
Parameter
Value
Description
[F2 (M COMP)] button
Threshold
-48–0 (dB)
Volume level at which
compression begins
Gain
-24– +24 (dB)
Output volume of compressor
Ratio
1:1, 2:1, 3:1, 4:1,
8:1,
∞
:1
Compression ratio
If “Ratio” is set to “1:1” the master comp effect will
not be applied (only the Gain setting will be
valid), regardless of the other settings.
Knee
SOFT, HARD
The sound’s attack at the
moment compression begins.
Attack
0.1, 0–100 (ms)
Time from when the volume
goes up the threshold level
until the compressor effect
applies
Release
10–100 (ms)
Time from when the volume
falls below the threshold level
until the compressor effect no
longer applies
[F3 (M EQ)] button
Type
SHELV
(Shelving),
Entire range above/below the
selected frequency range is
boosted/cut
PEAK
(MID: fixed to
“PEAK”)
The vicinity of the selected
frequency range is boosted/
cut
Q
0.5–8.0 (only
when Type is
set to “PEAK”)
Width of the frequency range
A higher Q narrows the
affected area.
Freq
(Frequency)
20–1k (LOW),
20–16K (MID),
1k–16k (HIGH)
(Hz)
Point at which the boost/cut
will occur
Gain
-12– +12 (dB)
Amount of boost/cut
Gain Reduction Meter and Output Meter
Restoring the Settings to Their Default
Values
Parameter
Value
Description
Gain reduction meter
Output meter
TD-20X_e.book 66 ページ 2009年6月8日 月曜日 午後3時50分
Summary of Contents for V-Drums TD-20X
Page 1: ... 5 1 0 0 0 0 6 8 6 2 0 1 ...
Page 2: ...Cover1 4 ...
Page 153: ...For EU Countries For China TD 20X_e book 153 ページ 2009年6月8日 月曜日 午後3時50分 ...
Page 155: ...Cover1 4 ...
Page 156: ... 5 1 0 0 0 0 6 8 6 2 0 1 ...