Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
87
9
Technical data
Pos: 68 /Schweissnaht/ Geräte/ SND40/2 Te chnische Daten/ SND40 Technische Da ten @ 0\mo d_1128582520078_501.do cx @ 709 @ 2 @ 1
9.1
Control unit SND40
Technical Data
Mains voltage:
85...264 VAC
Power consumption:
<110 W
Switch-on current:
<15 A/115V, <30 A / 230V
External fuse protection:
3.15 A medium-blow
Weight:
12 kg (26.5 lbs.)
Dimensions of industrial enclosure (L x W x H)* :
approx. 420 x 234 x 305 mm
*approx. 435 x 234 x 305 mm (starting May 2016)
Protection class of industrial enclosure:
IP54
Ambient temperature:
0 - 40 °C (operation)
Further characteristics:
• Embedded PC with Windows CE operating system for user interface
• Real-time computer (ARM7) for detection and positioning
• Programming and operation via 10" Touchscreen
• 31 programs, selectable via parallel interface / field bus interface
• 8 potential free optocoupler inputs 24 V DC with common ground potential; sinking inputs.
Specification:
−
min. switching voltage HIGH:
13 V DC
−
max. switching voltage HIGH:
30 V DC
−
min. switching voltage LOW:
0 V DC
−
max. switching voltage LOW:
4 V DC
• 8 potential free optocoupler outputs with common positive foreign supply
13… 30 V DC; sourcing outputs.
Specification:
−
max. switched voltage:
30 V DC
−
max. switched current:
50 mA (internal current limitation)
−
max. contact rating:
1.5 W (only resistive load)
Note!
For inductive load a coil protection diode is to be used. Otherwise the signal output
can be destroyed by the overvoltage when switching the inductive load off.