60
Chapter 5 Using Pedals to Control the Effects
When controlling the On/Off target with the
EXP pedal:
fig.05-150
* The range that can be selected changes according to the target
setting.
* When the “minimum” is set to a higher value than the
“maximum,” the change in the parameter is reversed.
* The values of settings can change if the target is changed after
the “minimum” and “maximum” settings have been made. If
you’ve changed the target, be sure to recheck the “minimum”
and “maximum” settings.
Source
fig.05-160d
This sets the controller (source) that affects the target
parameter.
Controllers that can be selected as the source are shown
below.
Setting Assign Input Sens
* This determines the global settings for Assign 1–8.
1.
Press PARAMETER [
] so that “Assign Input Sens”
is displayed.
2.
Rotate the PATCH/VALUE dial to adjust the setting’s
value.
Valid Settings: 0–100
Source Mode
fig.05-170d
This determines whether the control pedal will function as a
momentary type switch (such as the optional FS-5U).
* Set this to “Normal” when a latch-type foot switch (such as
the optional FS-5L) is connected, or when selecting something
other than a foot switch as the controller.
Value
Explanation
EXP PEDAL
EXP pedal (this unit)
CTL PEDAL
CTL pedal (this unit)
EXP SW
EXP pedal switch (this unit)
SUB EXP PDL
EXP pedal connected to the SUB EXP PEDAL/SUB CTL 1, 2 jack.
SUB CTL1, SUB CTL2
Foot switch connected to the SUB EXP PEDAL/SUB CTL 1, 2 jack.
INTERNAL PEDAL
Refer to “Internal Pedal System” (p. 61)
WAVE PEDAL
Refer to “Internal Pedal System” (p. 61)
INPUT LEVEL
This controls the level of the signal from the INPUT jack. Set the sen-
sitivity in response to the level with Assign Input Sens.
MIDI CC#01–31, 64–95
Control Change messages from an external MIDI device (1–31, 64–
95)
Off
On
Target Max
Off
Target Min
When the pedal
is fully advanced
When the pedal
is fully raised
When the pedal
is advanced halfway
EXP Pedal
On
Value
Explanation
Normal
The normal state is Off (minimum value), with the switch On (max-
imum value) only while the foot switch is depressed.
Toggle
The setting is toggled On (maximum value) or Off (minimum value)
with each press of the foot switch.