MAIN
:
AC TROUBLE
AC lost
MAIN
:
BELL LOOP
Siren trouble
FLASE CODE P=1
Code error
KITCHEN
:
FIR
Fire Loop in trouble
KP=03 COMM TRBL
The bus in trouble, such as No.3 keypad is in trouble
SYSTEM CLCOK
Clock not set
PS= 1 LOW BAT
Power Module Battery low. Such as No.1 power Expansion
Module is in trouble
PS=1 AC TRBL
Power Module in AC Trouble. Such as No.1 power Expansion
Module is in trouble
PS=1 BELL TRBL
Power Module Siren in Trouble. Such as No.1 power
Expansion Module is in trouble
PS=1 AUX TRBL
Power Module Stand-by Power is low. Such as No.1 power
Expansion Module is in trouble
PHONE LINE
Phone line in trouble
FIRE DOOR
:
DAY
Day time zone in trouble.
3.17 Zones characters
Every zone of RP248CN can be appoint its character, such as delay zone, instant zone,
emergency zone, firm zone, tamper zone, remote zone, utility output zone and so on. 24 hours
character will be always armed, no matter the system armed or not. As long as it is triggered, it will
be alarm. Such as emergency zone, tamper zone, emergency button, fire zone and so on.
Delay zone:
which has character of entry delay or/and exit delay. Exit delay is the period from the
time depress [ARM]/[STAY] to the system armed. Entry delay is the max time from entry to disarm
the system. Beyond delay time, will occur the system alarm.
Instant zone:
system alarm as soon as the zone triggered.
Emergency zone
+
be used to connect emergency button, 24-hours armed.
Fire zone
+
be used to connect smoke and gas detectors, 24- hours armed.
Tamper zone:
be used to connect detector’s tamper connector, 24- hours armed.
Remote zone:
be
used to connect remote control receiver zone, 24- hours armed.
3.18 System Partition and Control
RP248CN has 8 zones which can be operated separately.
Keypad and partition
Keypad can be appointed to any one or more partitions. Each partition can be set individual user
RP248CN User’s and Installer’s Manual