3.3 Terminal Software Operation
With the Dip Switch on the MK715x1 evaluation kit as the initial setting, pushing the reset button executes the
AT command application. If you input "at<CR>" which is AT command for command acceptance confirmation from
the terminal and then the result code string is output as shown below, UART communication between the PC and
MK715x1 evaluation kit is normal. Input of "at" command is not output because echo back from MK715x1 is
disabled.
Fig. 3-2 : Result code string output screen for command reception confirmation
Then, when you start the peripheral operation, type "atd <CR>" and the MK715x1 Evaluation Kit will start the
advertisement transmission. Alternatively, to initiate a central operation, type "ata <CR>" and the MK715x1
Evaluation Kit will initiate a scan and search for peripheral devices. The preparation for the MK715x1 side is
now complete.
3.4 BLE Tool operation
3.4.1 Application start
Tap the "BLE Tool" icon to start the application. (Fig. 3-3)