Introduction 

This user’s guide provides the necessary steps to operate the EVK of ROHM’s BD9E304FP4-LBZ 1-channel Buck DC/DC 

converter. This includes the external parts, operating procedures, and application data.   

 

Description 

This EVK has been developed for ROHM’s synchronous buck DC/DC converter customers evaluating BD9E304FP4-LBZ 

and outputs 12V from 24V input voltage. The BD9E304FP4-LBZ accepts a power supply input range of 4.5V to 36V and 

generates an output voltage ranging from (0.1 x V

IN

 or 0.7V) to 0.8 x V

IN

 

using external resistors. The operating frequency is 

fixed at 300 kHz. The Light Load Mode control provides good efficiency characteristics in light load conditions, which is 

ideal for applications that needs to lessen the standby power. The current mode control DC/DC converter provides high-

speed transient response performance. Additional protection functions include a built-in soft start function to prevent inrush 

current at startup, UVLO (Under Voltage Lock Out), TSD (Thermal Shutdown Detection), SCP (Short Current Protection), 

OCP (Over Current Protection), and OVP (Over Voltage Protection). 

 

Application 

Industrial Products as Factory Automation 

Secondary power supply and adapter equipment   

Telecommunication Devices 

 

Operating Limits

 

Parameter 

Min 

Typ 

Max 

Units 

Conditions 

Input Voltage 

18.0 

24.0 

36.0 

 

Output Voltage 

 

12.0 

 

 

Output Current Range 

 

 

3.0 

 

Operating Frequency 

 

300 

 

kHz 

 

Maximum Efficiency 

 

96.5 

 

Vin=24V, Iout=0.6A 

UVLO Detect Voltage 

 

3.9 

 

Vin sweep down 

UVLO Hysteresis Width 

 

350 

 

mV 

 

 

 

Summary of Contents for BD9E304FP4-EVK-002

Page 1: ...y is fixed at 300 kHz The Light Load Mode control provides good efficiency characteristics in light load conditions which is ideal for applications that needs to lessen the standby power The current m...

Page 2: ...EVK 2 Connect the VCC pin of the DC power supply to the VIN_F pin of the EVK 3 Connect the load to the VOUT_F and GND_F right side in EVK terminal of EVK When using an electronic load connect with the...

Page 3: ...210 25V X5R 20 MSAST32MAB5476MPNDT1 Previus name TMK325ABJ476MM P TAIYO YUDEN 2 C5 Capacitor 120pF 0603 0201 50V C0G 5 GRM0335C1H121JA01 Murata 1 C3 Capacitor 680pF 0603 0201 25V C0G 5 GRM0335C1E681JA...

Page 4: ...formation Number of Layers Material Board Size Copper Thickness 4 FR 4 67 5mm x 67 5mm x 1 6mmt 1oz 35 m The layout of BD9E304FP4 EVK 002 is shown below Figure 3 Top Layer Layout Top View Figure 4 Mid...

Page 5: ...tching Frequency vs Input Voltage VOUT 12V IOUT 3A Figure 9 Efficiency vs Output Current VOUT 12V 0 20 40 60 80 100 18 21 24 27 30 33 36 Operating Supply Current I OPR A Input Voltage VIN V 255 270 28...

Page 6: ...Rise up Waveform VEN 0V 24V IOUT 3A Figure 13 Shut down Waveform VEN 24V 0V IOUT 3A 2 0 1 5 1 0 0 5 0 0 0 5 1 0 1 5 2 0 0 500 1000 1500 2000 2500 3000 Output Voltage Change V CHANGE Output Current IO...

Page 7: ...002 Reference application data continued Figure 14 SW Waveform VIN 24V VOUT 12V IOUT 30 A Figure 15 SW Waveform VIN 24V VOUT 12V IOUT 3A Figure 16 Frequency Response VIN 24V VOUT 12V IOUT 3A VSW 5 V d...

Page 8: ...the Parts List Table 2 For reference Figure 17 shows the DC bias characteristics of GRM32EC72A106KE05 Murata listed as C2 in the Parts list Table 2 Actual capacitance degrades to 5 5 F under the cond...

Page 9: ...9 9 2022 ROHM Co Ltd No 64UG041E Rev 001 2022 2 User s Guide BD9E304FP4 EVK 002 Revision History Date Revision Number Description 14 Feb 2022 001 Initial release...