24/35
User
’
s Guide
© 2022 ROHM Co., Ltd.
No. 65UG013E Rev.001
July 2022
Figure 18:
“Error” status read
6.4.1.1. Write Register
To write any of the writable registers, the user must first enable the write-operation. This is done changing
the first bit of register 0x00:
1. Use the drop-down
menu to select “
ENABLED
” in register 0x00:
Figure 19: Select write-protection bit
2.
Now the binary value and the hexadecimal value change and “Edited” appears in the “Status” box.
Figure 20: Edit write-protection bit
3. P
ress “Write” button and the status box will change to “
Stored
”.
Figure 21: Write protection bit
If the write-
protection bit is not enabled first, no register can be written, and the indication “W
rite Fail
” will
appear in the status box next to the register.
Summary of Contents for BD868 0MUF-C Series
Page 1: ...BD868x0MUF C Camera PMIC EVK User Guide...
Page 27: ...BD868x0MUF C Camera PMIC User Guide 27 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...
Page 28: ...BD868x0MUF C Camera PMIC User Guide 28 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...
Page 29: ...BD868x0MUF C Camera PMIC User Guide 29 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...
Page 30: ...BD868x0MUF C Camera PMIC User Guide 30 35 2022 ROHM Co Ltd No 65UG013E Rev 001 July 2022...