Command Reference
R&S
®
ZNB/ZNBT
823
User Manual 1173.9163.02 ─ 38
Parameters for setting and query:
<CircuitModel>
SL | SC
Possible circuit models (character data); see
Example:
*RST; :CALC:TRAN:VNET:GLO:EMB:PAR:R? SC; R? SL
Query the default resistances for ground loop embedding. The
response is 10000000; 0.
CALC:TRAN:VNET:GLO:EMB:PAR:R SC, 2.2E+3
Increase the resistance for the Shunt C model to 2.2 kΩ.
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:GLOop:EMBedding:TNDefinition
<CircuitModel>
Selects the circuit model for ground loop embedding.
Suffix:
<Ch>
.
Channel number.
Parameters:
<CircuitModel>
FIMPort | SL | SC | SG
Possible circuit models (character data); see
ground loop port embedding/deembedding
*RST:
FIMPort
Example:
See
CALCulate<Ch>:TRANsform:VNETworks:GLOop:
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:FSIMulator[:STATe]
<Enable>
De/activates the "Fixture Simulator" switch that allows to disable and (re-)enable the
configured deembedding, embedding, balanced ports, and port impedance settings for
the selected channel.
Suffix:
<Ch>
.
Channel number
Parameters:
<Enable>
Manual operation:
See
CALCulate<Ch>:TRANsform:VNETworks:PPAir:DEEMbedding:DELete
Deletes all port sets (including port pairs) previously defined for deembedding.
Suffix:
<Ch>
.
Channel number
SCPI Command Reference