Segment List
Defines the individual limit line segments.
The table contains an automatically assigned current number for each segment plus
the following editable columns:
●
"Type" indicates whether the segment belongs to an "Upper" or a "Lower" limit line,
or if the limit check at the segment is switched "Off". Switching off the limit check
does not delete the segment but changes its screen color.
●
"Start Stimulus" is the stimulus (x-axis) value of the first point of the segment.
●
"Stop Stimulus" is the stimulus (x-axis) value of the last point of the segment.
●
"Start Response" is the response (y-axis) value of the first point of the segment.
●
"Stop Response" is the response (y-axis) value of the last point of the segment.
The limit line segment is calculated as a straight line connecting the two points
(<Start Stimulus>, <Start Response>) and (<Stop Stimulus>, <Stop Response>);
see
Chapter 4.4.1.1, "Rules for Limit Line Definition"
Remote command:
CALCulate<Chn>:LIMit:SEGMent:COUNt?
CALCulate<Chn>:LIMit:SEGMent<Seg>:TYPE
CALCulate<Chn>:LIMit:SEGMent<Seg>:STIMulus:STARt
CALCulate<Chn>:LIMit:SEGMent<Seg>:STIMulus:STOP
CALCulate<Chn>:LIMit:SEGMent<Seg>:AMPLitude:STARt
CALCulate<Chn>:LIMit:SEGMent<Seg>:AMPLitude:STOP
CALCulate<Chn>:LIMit:CONTrol[:DATA]
CALCulate<Chn>:LIMit:CONTrol:SHIFt
CALCulate<Chn>:LIMit:DATA
CALCulate<Chn>:LIMit:LOWer[:DATA]
CALCulate<Chn>:LIMit:LOWer:SHIFt
CALCulate<Chn>:LIMit:UPPer[:DATA]
CALCulate<Chn>:LIMit:UPPer:FEED
Add / Insert / Delete / Delete All
The first four buttons below the segment list extend or shorten the list. The analyzer
places no restriction on the number of segments in a limit line.
●
Add
adds a new segment to the end of the list. The new segment extends from the
"Stop Stimulus" value of the last segment to the end of the sweep range. Its
response values are equal to the "Stop Response" value of the last segment.
●
Insert
adds a new segment before the active segment (marked by a blue back-
ground in the first column of the segment list). The new segment extends from the
"Stop Stimulus" value of the segment before the active segment to the "Start Stim-
ulus" value of the active segment. Its response values are equal to the "Start
Response" value of the active segment. The segment numbers in the list are adap-
ted.
If no segment is active, "Insert" is equivalent to "Add".
●
Delete
removes the selected segment from the list.
●
Delete All
clears the entire segment list so it is possible to define or load a new
limit line.
Remote command:
CALCulate<Chn>:LIMit:DELete:ALL