Measurements and Result Displays
R&S
®
VSE-K149
17
User Manual 1179.3315.02 ─ 01
Spectrum Mask Passed
Passed if transmit PSD mask limits are met
Ranging
RMarker [ps]
Ranging marker position defined in IEEE
802.15.4-2020 and IEEE 802.15.4z-2020, relative to
capture buffer
To estimate the time difference between several
captured packets, the RMarker can be evaluated.
For each result type, several values are displayed.
●
Sel packet
Values measured for the selected packet.
●
Average
Average value measured over all packets.
●
Min
Lowest value measured over all packets.
●
Max
Highest value measured over all packets.
Remote command:
LAY:ADD? '1',RIGH,RSUM
Chapter 6.5.2, "Result Summary"
Symbol Phase Jitter
Displays a histogram of the phase jitter of symbols in SYNC section of each packet.
Remote command:
LAY:ADD? '1',RIGH,SJPH
Symbol Time Jitter
Displays a histogram of the time jitter of symbols in SYNC section of each packet.
Evaluation Methods for HRP UWB