Setting up
R&S
®
TS-PSM4
21
User Manual 1178.2796.02 ─ 01
Figure 6-2: Opening the terminal contact CH16_COM
Figure 6-3: Over the upper opening of the terminal the metal spring can be pressed down
The wire to be mounted is now inserted into the exposed lower opening. To establish a
good connection the wire must be free of its insulation by a length of about 6 mm. After
removing the screwdriver from the upper opening the metal spring will spring back and
clamp the inserted wire firmly and form a good connection with low contract resistance.
Channel wiring of the R&S TS-PSM4B (variant 02)