Remote control commands
R&S
®
SMM100A
871
User Manual 1179.1341.02 ─ 05
[:SOURce]:BB:IMPairment:BBMM<ch>:POFFset
<PhaseOffset>
[:SOURce]:BB:IMPairment:IQOutput<ch>:POFFset
<PhaseOffset>
[:SOURce]:BB:IMPairment:RF<ch>:POFFset
<PhaseOffset>
Adds an additional phase offset after the stream mapper.
You can shift the phase at the different stages in the signal generation flow, see:
●
Parameters:
<PhaseOffset>
float
Range:
-999.99 to 999.99
Increment: 0.01
*RST:
0
Example:
SOURce:BB:IMPairment:RF1:POFFset 0
Manual operation:
See
[:SOURce<hw>]:BB:IMPairment:OPTimization:MODE
<Mode>
Sets the optimization mode.
Option: R&S
SMM100A-K544: the value selected here is used also as optimization
mode for the user-defined frequency response corrections, and vice versa.
See user manual R&S
SMM-K544 User-Defined Frequency Response Correction.
Parameters:
<Mode>
FAST | | QHIGh | QHTable
FAST
Optimization by compensation for I/Q skew.
QHTable
Improved optimization by maintained speed.
QHIGh
Optimization by compensation for I/Q skew and frequency
response correction.
This mode interrupts the RF signal. Do not use it in combination
with the uninterrupted level settings and strictly monotone
modes RF level modes.
(See
[:SOURce<hw>]:POWer:LBEHaviour
*RST:
FAST
Example:
:SOURce1:IQ:SOURce BASeband
:SOURce1:BB:IMPairment:OPTimization:MODE FAST
Manual operation:
See
13.16.4.7
SOURce:BB:GRAPhics subsystem
This subsystem contains the commands used to setup the graphical display.
SOURce subsystem