Multi-instrument setups
R&S
®
SMM100A
476
User Manual 1179.1341.02 ─ 05
9.6
I/Q analog output settings
Required Options
The equipment layout for output of analog I/Q signal includes:
●
Base unit
Incl. output the baseband signal at the single-ended outputs
●
Option differential analog I/Q outputs (R&S
SMM-K17)
Access
The analog output connectors I/Q are located on the R&S
SMM100A rear panel, see
Chapter 9.3.4.2, "Overview of the baseband and RF output signals"
The block diagram displays the "I/Q OUT" connector in a folded state. The analog out-
put connectors are inactive (gray LEDs).
1
2
3
Figure 9-5: Representation of the analog output interface
1 = Analog output interface state: gray =
inactive; blue =
active
2 = Analog output connector name
3 = Mapped I/Q stream
To configure the "I/Q Analog Output" settings
1. Select the "I/Q OUT" symbol to unfold the "I/Q Analog" block.
2. To route or reroute the signal to the analog outputs, select the "I/Q Stream Mapper"
block.
3. To enable the baseband signal at the analog outputs, select "Block Diagram > I/Q
Analog > I/Q Analog On".
4. To access the dialog box for configuring the analog output signal, select "I/Q Ana-
log > I/Q Analog Settings > General".
I/Q analog output settings