![Rohde & Schwarz SMM100A User Manual Download Page 224](http://html.mh-extra.com/html/rohde-and-schwarz/smm100a/smm100a_user-manual_1477939224.webp)
Configuring the internal baseband source
R&S
®
SMM100A
224
User Manual 1179.1341.02 ─ 05
The "ARB > Trigger In (MSW)" settings display the currently output segment: "Cur-
rent Segment Name = Seg#0" and "Curent Segment Index = 0". Seg#0 is output
continuously.
5. Set "ARB > Trigger In (MSW) > Segment = 3" to output the second segment in the
sequence order.
The parameter "ARB > Trigger In (MSW) > Current Segment Index" changes to
segment index 3. Seg#3 is output continuously.
6. Execute "ARB > Trigger In > Execute Trigger" to restart Seg#3.
7. Set "ARB > Trigger In (MSW) > Segment = 2" to output the third segment in the
sequence order.
Seg#2 is output continuously.
To switch over to Seg#0, change the "ARB > Trigger In (MSW) > Current Segment
Index", etc.
Tip:
The ARB sequencer mode provides the necessary settings to achieve the
same goal in a more convenient way, see
"To configure a multi-segment sequence
Faster flexible dynamic switch over
When using
remote control
via an external computer, the following settings enable
switching times of approx. 20 ms for segments with the same sample rate and approx.
200 ms for segments with different sample rates:
●
"ARB > Trigger In (MSW) > Next Segment Mode = Next Segment"
●
"ARB > Trigger In > Trigger Mode = Auto"
●
"ARB > Trigger In > Trigger Source = Internal"
To generate a multi-segment signal without signal interruptions
Testing receivers requires a continuous output of different test signals without interrupt-
ing the signal. The test signals then produce a complex total signal with no signal gaps
on switch over. Control procedures can use a simulated back channel of the receiver
(trigger line or remote control).
Switching times depend on the length of the segment currently being output, because
switch over to the next segment does not take place until the current segment ends.
To overcome wrap-around problems and generate multi-segment signals without signal
gaps between the segments, consider the following settings:
1. Enable "ARB > Trigger In (MSW) > Next Segment Mode = Next Segment Seam-
less"
2. Select "ARB > Trigger In > Trigger Mode = Auto"
3. Select "ARB > Trigger In > Trigger Source = Internal"
Generating multi-segment waveform files