Configuring the internal baseband source
R&S
®
SMM100A
195
User Manual 1179.1341.02 ─ 05
●
OFDM Signal Generation
4.7.3
Notch filter settings
Access:
1. Select "System Configuration" with separate sources.
Select "System Configuration > Fading/Baseband Config." >
"BB Source Config =
Separted"
.
2. Select "Baseband > ARB > Notch Filter".
3. Observe the value of the parameter "ARB > General > Clock Frequency".
It indicates and defines the resolution of frequency offsets of the individual notches.
4. Set the number of notches and define their settings:
a) "Number of Notches = e.g. 3"
b) For notch#1, set "Frequency Offset = 0" and "Notch Bandwidth, MHz = 0.6".
c) For notch#1, set "State = On".
5. Select "Notch Filter > Apply" to trigger the instrument to adopt the notch filter set-
tings.
6. Select "ARB > General > State > On".
Comprises the settings for enabling the notch filter and indicates the clock fre-
quency for the waveform.
The remote commands required to define these settings are described in
The notched filters settings are available for the ARB generator and four digital stand-
ards. The provided settings are identical, merely the access to the settings and the
remote control commands are different.
Generating notched signals