Example:
SYST:IDEN USER
selects the user defined identification string.
Manual operation:
See
:SYSTem:LANGuage
<Language>
Sets the remote control command set.
The instrument can also be remote controlled via the command set of several other
generators, for example HP generator. See the Application Note
at the down-
load area of the product site on the Internet.
Note
: While working in a emulation mode, the instrument's specific command set is
disabled, i.e. the SCPI command
SYSTem:LANGuage
will be discarded.
The return to the SCPI command set of the R&S
SMF can only be performed by using
the appropriate command of the selected command set. For example, the HP com-
mand
EX
returns to the instrument-specific GPIB command set (selection
SYST:LANG
'HPxxxx'
).
Parameters:
<Language>
string
Example:
SYSTem:LANGuage "SCPI"
sets the SCPI command set.
Manual operation:
See
:SYSTem:PROTect<ch>[:STATe]
<State>[, <Key>]
Activates/deactivates the specified protection level.
Parameters:
<State>
select
*RST:
1
Setting parameters:
<Key>
integer
The respective functions are disabled when the protection level
is activated. No password is required for activation. A password
must be entered to deactivate the protection level. The pass-
word for the first level is 123456.
This protection level can be used to lock-out internal adjust-
ments.
Example:
SYSTem:PROTect1:STATe ON
activates protection level 1. Internal adjustments are only possi-
ble after deactivating the lock-out.
SYSTem:PROTect1:STATe OFF,123456
deactivates protection level 1. Internal adjustments are enabled
again.