Remote Control Commands
R&S
®
SMF100A
578
Operating Manual 1167.2319.02 ─ 12
Example:
SYST:DLOC ON
locks the display. To unlock the display
SYST:DLOC OFF
.
Manual operation:
See
:SYSTem:KLOCk
<State>
K
eyboard
LOC
k disables the front panel keyboard of the instrument including the
LOCAL key, or enables it again (OFF).
The command disables also the front panel keyboard of the instrument including the
LOCAL key.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
SYST:KLOC ON
locks the front panel and external controls. To enable the con-
trols, set
SYST:KLOC OFF
.
Manual operation:
See
:SYSTem:ULOCk
<Mode>
Locks or unlocks the user interface of the instrument.
Parameters:
<Mode>
ENABled | DONLy | DISabled
ENABled
Unlocks the display and all controls for the manual operation.
DONLy
Locks the controls for the rmanual operation of the instrument.
The display shows the current settings.
DISabled
Locks the controls for the rmanual operation, and enables
remote operation over VNC. The display shows the current set-
tings.
*RST:
ENABled
Example:
SYST:ULOC ON
activates the user interface lock.
Manual operation:
See
:SYSTem:COMMunicate:GPIB:LTERminator
<LTerminator>
Sets the terminator recognition for remote control via GPIB bus.
SYSTem Subsystem