Remote Control Commands
R&S
®
SMF100A
492
Operating Manual 1167.2319.02 ─ 12
Manual operation:
See
[:SOURce]:LFOutput:SWEep:VOLTage:DWELl
<Dwell>
The command sets the time taken for each level step of the sweep.
Parameters:
<Dwell>
float
Range:
1E-3 to 100
Increment: 100E-6
*RST:
15E-3
Default unit: s
Example:
SOUR:LFO:SWE:VOLT:DWEL 12m
sets a dwell time of 12 ms for a level sweep.
Options:
R&S SMF-B20
Manual operation:
See
" Dwell Time - LF Level Sweep "
[:SOURce]:LFOutput:SWEep:VOLTage:EXECute
The command triggers a sweep. The sweep to be executed depends on the set sweep
mode (
[:SOURce]:LFOutput:SWEep:VOLTage:MODE
to the manual-control command
Execute Trigger
.
The command triggers an event and therefore has no query form and no
*RST
value.
Example:
SOUR:LFO:SWE:VOLT:MODE STEP
sets the STEP trigger mode, i.e. a trigger starts the sweep ini-
tially, and then the sweep is generated continously.
SOUR:LFO:SWE:VOLT:EXEC
triggers a level sweep.
Usage:
Event
Options:
R&S SMF-B20
Manual operation:
See
" Execute Single Sweep - LF Level Sweep "
[:SOURce]:LFOutput:SWEep:VOLTage:LFSource
<LfSource>
The command selects the source for the LF level sweep.
Parameters:
<LfSource>
LF1 | LF2
*RST:
LF1
Example:
SOUR:SWE:LFO:VOLT:LFS LF2
selects LF generator 2 as the LF frequency sweep source.
Options:
R&S SMF-B20
Manual operation:
See
" Generator - LF Level Sweep "
SOURce Subsystem