Remote Control Commands
R&S
®
SMF100A
407
Operating Manual 1167.2319.02 ─ 12
:SENSe[:POWer]:SWEep:FREQuency:TIMing[:MODE]
<Mode>
Selects the mode in terms of speed and precision of the response of a measurement.
Parameters:
<Mode>
FAST | NORMal | HPRecision
FAST
Selection FAST leads to a fast measurement with a short inte-
gration time for each measurement step.
NORMal
NORMal leads to a longer but more precise measurement due
to a higher integration time for each step.
*RST:
FAST
Example:
SENS:SWE:FREQ:TIM:MODE FAST
the fast measurement mode is selected.
Options:
Option R&S SMF-K28
Manual operation:
See
:SENSe[:POWer]:SWEep:FREQuency:YSCale:AUTO
<Auto>
Activates autoscaling of the Y axis of the diagram.
Parameters:
<Auto>
OFF | CEXPanding | FEXPanding | CFLoating | FFLoating
OFF
Auto scaling is deactivated. If switching from activated to deacti-
vated Auto scaling, the scaling is maintained.
CEXPanding | FEXPanding
Auto scale is activated. The scaling of the Y-axis is selected in
such a way, that the trace is always visible. To this end, the
range is expanded if the minimum or maximum values of the
trace move outside the current scale. The step width is 5 dB for
selection course and variable in the range of 0.2 db to 5 dB for
selection fine.
CFLoating | FFLoating
Auto scale is activated. The scaling of the Y-axis is selected in
such a way, that the trace is always visible. To this end, the
range is either expanded if the minimum or maximum values of
the trace move outside the current scale or scaled down if the
trace fits into a reduced scale. The step width is 5 dB for selec-
tion course and variable in the range of 0.2 db to 5 dB for selec-
tion fine.
*RST:
CEXPanding
Example:
SENS:SWE:FREQ:YSC:AUTO OFF
deactivates auto scale
Options:
Option R&S SMF-K28
Power Sensor Measurement Subsystems