Remote-Control Commands
R&S
®
SMCVB-K168
65
User Manual 1179.1064.02 ─ 03
[:SOURce<hw>]:BB:DVBS2:PAYLoad
<Payload>
Defines the payload area content of the
packet.
Parameters:
<Payload>
0xFF | 0x00 | PRBS
*RST:
PRBS
Manual operation:
See
[:SOURce<hw>]:BB:DVBS2:PID
<PID>
.
Parameters:
<PID>
float
Range:
#H0 to #HFFF
Increment: 1
*RST:
#H0
Manual operation:
See
[:SOURce<hw>]:BB:DVBS2:PIDTestpack
<PIDTestPacket>
If a header is present in the test packet ("Test TS Packet > Head/184 Payload"), you
can specify a fixed or variable packet identifier (PID).
Parameters:
<PIDTestPacket>
VARiable | NULL
*RST:
NULL
Manual operation:
See
[:SOURce<hw>]:BB:DVBS2:PRBS[:SEQuence]
<PRBS>
Sets the length of the PRBS sequence.
You can select a PRBS 15 or a PRBS 23 sequence as specified by
Parameters:
<PRBS>
P15_1 | P23_1
*RST:
P23_1
Manual operation:
See
5.2.4
IP Subsystem
The
SOURce:BB:INPut:IP
subsystem contains the commands for configuring input
IP data from a local IP data network.
Input Commands