Remote Control Commands
R&S
®
SMC100A
268
Operating Manual 1411.4060.32 ─ 04
Example:
LFO:FREQ:STAR
sets the start frequency to 2 kHz.
LFO:FREQ:STOP
sets the stop frequency to 20 kHz
LFO:SWE:SPAC LIN
sets linear sweep spacing.
LFO:SWE:POIN 11
sets 11 sweep steps for linear sweep spacing. The sweep step
width (
STEP
) is automatically set to 2 kHz.
[:SOURce]:LFOutput:SWEep[:FREQuency]:SHAPe
<Shape>
The command sets the cycle mode for a sweep sequence (shape).
Parameters:
<Shape>
SAWTooth | TRIangle
SAWTooth
One sweep runs from start to stop frequency. Each subsequent
sweep starts at the start frequency, i.e. the shape of the sweep
sequence resembles a sawtooth.
TRIangle
One sweep runs from start to stop frequency and back, i.e. the
shape of the sweep resembles a triangle. Each subsequent sweep
starts at the start frequency.
*RST:
SAWTooth
Example:
SOUR:LFO:SWE:SHAP TRI
selects the sweep cycle with alternating ascending and descend-
ing sweep directions.
[:SOURce]:LFOutput:SWEep[:FREQuency]:SPACing
<Spacing>
The command selects linear or logarithmic sweep spacing.
Parameters:
<Spacing>
LINear | LOGarithmic
*RST:
LINear
Example:
LFO:SWE:SPAC LIN
selects linear sweep spacing.
[:SOURce]:LFOutput:SWEep[:FREQuency]:STEP[:LINear]
<Linear>
The command sets the step width for the linear sweep.
This command is linked to the com-
mand
:LFOutput:SWEep[:FREQuency]:POINts
as follow.
●
for
STARt < STOP:
POINts = (((STOP-STARt) / STEP:LIN) + 1
SOURce Subsystem