Instrument Function
R&S
®
SMC100A
152
Operating Manual 1411.4060.32 ─ 04
5.4.4.1
Phase Modulation Menu
To open the "Phase Modulation" menu, select "Modulation > Configure > Phase Modu-
lation" or use the MENU key under "Modulation".
In the upper section of the menu, the modulation source is selected and the modulation
switched on. The modulation source can be selected independently for the different
modulation types and the LF output.
The configuration of the selected external or internal modulation source is performed in
the lower section of the "LF Output" menu (internal source only) or in the "Mod Gen" block.
These settings affect all modulations which use the same modulation sources.
An LF generator and a pulse generator are available as internal sources.
State
Activates/deactivates PhiM modulation.
Activation of PhiM deactivates frequency modulation.
SCPI command:
PhiM Source
Selects the source for the PhiM signal.
"Internal"
Selects the internal LF generator as the source for PhiM modulation.
"External"
Selects the external source.
The external signal is input via the MOD EXT connector.
SCPI command:
PhiM Deviation
Sets the modulation depth in RAD or degrees.
The maximal deviation depends on the RF frequency set and the selected modulation
mode (see data sheet). It is possible to enter a deviation that is too high for a certain RF
frequency or to vary the RF frequency to a range in which the deviation can no longer be
set. In this case the maximally possible deviation is set and an error message is displayed.
SCPI command:
LF Gen Frequency
Sets the frequency of the LF generator.
Modulations