Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
IQ:SWAP ON
swaps the I and Q channel.
Manual operation:
See
[:SOURce<hw>]:IQ:WBSTate
<WbState>
Activates wideband mode.
This setting automatically optimizes the settings for wideband modulation signals
(>5
MHz, State ON).
Parameters:
<WbState>
0 | 1 | OFF | ON
*RST:
0
Example:
IQ:WBST ON
switches to wideband mode.
Manual operation:
See
12.16.9
SOURce:IQ:OUTPut Subsystem
The
SOURce:IQ:OUTPut
subsystem contains the commands for configuring the ana-
log and digital I/Q output signals.
For information about the required options, see:
●
Chapter 8.7, "I/Q Analog Output Settings"
For information on the connector and interfaces the analog and digital I/Q signals are
output at, see:
Chapter 8.4.1.4, "Overview of the Input and Output Signals and Interfaces"
12.16.9.1
SOURce:IQ:OUTPut:ANALog Commands
This section describes the commands of the output of an analog I/Q signal.
SOURce Subsystem