![Rohde & Schwarz SMBV100B User Manual Download Page 804](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881804.webp)
Remote Control Commands
R&S
®
SMBV100B
802
User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:AWGN:POWer:SUM:PEP?
Queries the peak envelope power of the overall signal comprised of noise signal plus
useful signal.
Return values:
<Pep>
float
Range:
-145 to 20
Increment: 0.01
*RST:
0
Example:
Example "Generating an additive noise signal"
Usage:
Query only
Manual operation:
See
"C Noise PEP, Noise PEP (Total Band-
width), C Interferer PEP, Interferer PEP"
[:SOURce<hw>]:AWGN:FREQuency:TARGet
<Target>
Sets the desired frequency of the sine wave.
Parameters:
<Target>
float
Range:
-40E6 to 40E6
Increment: 0.01
*RST:
0
Example:
Example "Generating a CW interferer signal"
Manual operation:
See
[:SOURce<hw>]:AWGN:FREQuency:RESult?
Queries the actual frequency of the sine wave.
Return values:
<Result>
float
Range:
-40E6 to 40E6
Increment: 0.01
*RST:
0
Example:
Example "Generating a CW interferer signal"
Usage:
Query only
Manual operation:
See
"Resulting CW Frequency Offset"
12.16.4.6
SOURce:BB:IMPairment Subsystem
This subsystem contains the commands for the analog and digital I/Q impairments.
SOURce Subsystem