Remote Control Commands
R&S
®
SMBV100B
779
User Manual 1178.4460.02 ─ 03
Parameters:
<Source>
INTernal
*RST:
INTernal
Example:
See
Example "Managing waveform files"
Manual operation:
See
12.16.4.4
SOURce:BB:MCCW Subsystem
This subsystem contains the commands for setting the Multi-Carrier CW signals.
The generation of multi-carrier CW signals requires an instrument equipped with the
software options R&S
SMBVB-K61.
Common Suffixes
The following common suffixes are used in remote commands:
Suffix
Value range
Description
SOURce<ch>
1
Available baseband signals
OUTPut<ch>
1 to 3
Available markers
Required options
See
Chapter 3.9.1, "Required Options"
Programming Examples
Generating a multi-carrier signal to test the frequency response of a DUT
// ******************************************************************
// Reset the instrument first
// ******************************************************************
*RST; *CLS
// ******************************************************************
// Configuring and enabling the multi-carrier signal
// ******************************************************************
SOURce:BB:MCCW:CARRier:COUNt 81
SOURce:BB:MCCW:CARRier:SPACing 1E6
// Set the number of carriers and their distance
// Further settings stay in default state (for example trigger settings)
SOURce:BB:MCCW:STATe ON
// Enable signal generation
OUTPut ON
// Enable the signal output
SOURce Subsystem