Remote Control Commands
R&S
®
SMBV100B
745
User Manual 1178.4460.02 ─ 03
// ******************************************************************
// Trigger the signal caulation and load the waveform in the ARB generator
// ******************************************************************
// Define the file name of the multi carrier output file, e.g. "3gpp_mc"
SOURce1:BB:ARBitrary:MCARrier:OFILe "3gpp_mc"
// Create and load the multi carrier waveform file in the ARB generator
SOURce1:BB:ARBitrary:MCARrier:CLOad
// Alternatively: create the multi carrier waveform and
// load it subsequently in the ARB generator
// SOURce1:BB:ARBitrary:MCARrier:CREate
// SOURce1:BB:ARBitrary:WAVeform:SELect"3gpp_mc"
// Activate the ARB generator
SOURce1:BB:ARBitrary:STATe ON
// ******************************************************************
// Use the save/recall function to store the settings
// ******************************************************************
// Query available settings files in a specified directory
MMEM:CDIR "/var/user/waveform"
SOURce1:BB:ARBitrary:MCARrier:SETTing:CATalog?
// mcar1, mcar2
// the directory contains the settings files mcar1.arb_multcarr and mcar2.arb_multcarr
SOURce1:BB:ARBitrary:MCARrier:SETTing:STORe "3gpp_mc"
General Commands
[:SOURce<hw>]:BB:ARBitrary:PRESet
Sets all ARB generator parameters to their default values.
Example:
See
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:STATe
<State>
Enables the ARB generator.
A waveform must be selected before the ARB generator is activated.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Manual operation:
See
SOURce Subsystem