Remote Control Commands
R&S
®
SMBV100B
722
User Manual 1178.4460.02 ─ 03
Parameters:
<Deviation>
float
The value range depends on the selected symbol rate (see data
sheet).
Range:
-40E6 to 40E6
Increment: 0.5
Default unit: Hz
Example:
SOURce:BB:DM:FORMat FSKVar
SOURce:BB:DM:FSK:VARiable:TYPE FSK4
SOURce:BB:DM:FSK:VARiable:SYMBol0:DEViation 135000
Manual operation:
See
[:SOURce<hw>]:BB:DM:FSK:VARiable:TYPE
<Type>
The command selects the modulation type for Variable FSK.
Parameters:
<Type>
FSK4 | FSK8 | FSK16
*RST:
FSK4
Example:
See
[:SOURce<hw>]:BB:DM:FSK:VARiable:
Manual operation:
See
[:SOURce<hw>]:BB:DM:APSK16:GAMMa
<Gamma>
Sets the gamma function
γ
for the 16APSK modulation.
Parameters:
<Gamma>
G2D3 | G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy
: G = Gamma function,
xy
= code rate
*RST:
G2D3
Example:
SOURce1:BB:DM:FORMat APSK16
SOURce1:BB:DM:APSK16:GAMMa G9D10
Manual operation:
See
[:SOURce<hw>]:BB:DM:APSK32:GAMMa
<Gamma>
Sets the gamma function
γ
for the 32APSK modulation.
Parameters:
<Gamma>
G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy
: G = Gamma function,
xy
= code rate
*RST:
G3D4
SOURce Subsystem