Configuring the RF Signal
R&S
®
SMBV100B
370
User Manual 1178.4460.02 ─ 03
"Gauss"
Generates the noise power according to a Gaussian distribution.
"Equal"
Generates an evenly distributed noise.
Remote command:
[:SOURce<hw>]:NOISe:DISTribution
Bandwidth
Sets the noise bandwidth as distinct value.
You can set the bandwidth between 100
kHz and 10
MHz in 100
KHz steps.
Remote command:
[:SOURce<hw>]:NOISe:BANDwidth|BWIDth
[:SOURce<hw>]:NOISe:BWIDth:STATe
6.11.4.7
LF Signal Output Settings
Access:
► Select "RF" > "Analog Modulation" > "LF Output".
In the "LF Output" tab, you can configure the signal at the LF outputs, determine
the output voltage or add a DC offset. Activate both paths to output the sum signal
of the two sources.
See also
Settings:
Analog Modulations