![Rohde & Schwarz SMBV100B User Manual Download Page 239](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881239.webp)
Configuring the Internal Baseband Source
R&S
®
SMBV100B
237
User Manual 1178.4460.02 ─ 03
Delay Start
Sets the delay of the carrier marked by "Carrier Start".
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:DELay[:STARt]
Delay Step
Sets the step width that is used to increment the delay
The resulting delay in the carrier table equals:
Delay =
"Delay Start" + n*"Delay Step"
,
Where
n
is a value between 0 and ("Carrier Stop" - "Carrier Start").
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:DELay:STEP
Input Waveform File
Accesses the standard "File Select" function for selecting the input file. The input file
contains the I/Q signal to be modulated onto
all carriers
of the selected carrier range.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:FILE
Apply Assistant Settings
Transfers the assistant settings to the carrier table.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:EXECute
3.8.3.4
Carrier Graph
Access:
1. Select "Baseband > ARB > General > Multi Carrier".
Generating Multi-Carrier Signals