![Rohde & Schwarz SMBV100B User Manual Download Page 235](http://html.mh-extra.com/html/rohde-and-schwarz/smbv100b/smbv100b_user-manual_1477881235.webp)
Configuring the Internal Baseband Source
R&S
®
SMBV100B
233
User Manual 1178.4460.02 ─ 03
3.8.3.2
Carrier Table Settings
Access:
1. Select "Baseband > ARB > General > Multi Carrier".
2. Select "ARB: Multi Carrier > Carrier Table"
This tab comprises the settings of the individual carriers. A selectable carrier range
can be set with the aid of the optional "Carrier Table Assistant".
The settings of all available carriers are displayed in table form. Previously applied
assistant settings can be further refined. The number of lines corresponds to the
number of carriers.
The phase/deg settings are only valid if optimization of the crest factor is disabled
("Crest Factor Mode" =
Off).
Use the "Carrier Graph" tab to visualize the selected multi-carrier configuration.
Settings:
Generating Multi-Carrier Signals