Remote Control Commands
R&S
®
SMBV100A
711
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Mode>
RESTart | PULSe | PATTern | RATio | TRIGger
RESTart
A brief marker signal is generated at the start of the waveform.
PULSe
A pulsed marker signal is generated. The pulse frequency (=
sample rate/divider) is defined with the
SOUR:BB:MCCW:TRIG:OUTP:PULSe:DIVider
command and
can be queried with the
SOUR:BB:MCCW:TRIG:OUTP:PULSe:FREQuency?
command.
PATTern
A marker signal is generated with the aid of a user-definable bit
pattern. The bit pattern is entered with the aid of command
SOURce:BB:MCCW:TRIGger:OUTPut:PATTern
. The bit pat-
tern is a maximum of 32 bits long.
RATio
A regular marker signal corresponding to the Time Off / Time On
specifications in the commands
SOURce:BB:MCCW:TRIGger:OUTPut:OFFT
and
SOURce:BB:MCCW:TRIGger:OUTPut:ONT
is generated.
TRIGger
A received internal or external trigger signal is output at the
marker connector.
*RST:
RESTart
Example:
BB:MCCW:TRIG:OUTP2:MODE PULS
selects the pulsed marker signal on output MARKER 2.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:OFFTime
<OffTime>
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:ONTime
<OnTime>
Sets the number of samples in a period (ON time + OFF time) during which the marker
signal in setting
SOURce:BB:MCCW:TRIGger:OUTPut:MODE RATio
on the marker
outputs is ON.
Parameters:
<OnTime>
integer
Range:
1 to 16777215
*RST:
1
Example:
BB:MCCW:TRIG:OUTP2:ONT 20
sets an ON time of 20 samples for marker 2.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PATTern
<Pattern>, <BitCount>
Sets the bit pattern used to generate the marker signal.
SOURce Subsystem