![Rohde & Schwarz SMBV100A Operating Manual Download Page 613](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735613.webp)
Remote Control Commands
R&S
®
SMBV100A
598
Operating Manual 1176.8016.02 ─ 17
Usage:
Query only
Manual operation:
See
" Noise Power (Total Bandwidth) - AWGN "
[:SOURce<hw>]:AWGN:POWer:RMODe
<RMode>
In Additive Noise and CW Interferer (
SOUR:AWGN:MODE ADD|CW
) modes and Display
Mode set to RF (
AWGN:DISP:MODE RF
), selects the mode for setting the interfering
signal.
Parameters:
<RMode>
CARRier | NOISe
CARRier
The carrier power is kept constant when the C/N value or Eb/N0
value is changed. The noise power is adjusted.
NOISe
The noise power is kept constant when the C/N value or Eb/N0
value is changed. The carrier power is adjusted.
*RST:
CARRier
Example:
SOURce:AWGN:MODE ADD
selects Additive Noise mode.
SOURce:AWGN:DISP:MODE RF
sets the display mode to RF
SOURce:AWGN:POWer:RMODe NOISe
selects Reference Mode Noise. The noise power is kept con-
stant when the C/N value or Eb/N0 value is changed. The carrier
power is adjusted.
Manual operation:
See
[:SOURce<hw>]:AWGN:POWer:SUM?
In Additive Noise and CW Interferer (
SOUR:AWGN:MODE ADD|CW
) modes, queries the
overall power of the noise signal plus useful signal.
Return values:
<Sum>
float
Range:
-145 to 20
Increment: 0.01
*RST:
0
Example:
SOURce:AWGN:POWer:SUM?
queries the overall power of the noise signal plus useful signal.
Usage:
Query only
Manual operation:
See
" C Noise Power / Noise Power (System
Bandwidth) / C Interferer Power / Interferer
Power "
SOURce Subsystem