Instrument Function
R&S
®
SMBV100A
271
Operating Manual 1176.8016.02 ─ 17
Pulse Width - Pulse Generator
Sets the width of the generated pulse. The width determines the pulse length. The
pulse width must be at least 20 ns less than the set pulse period.
Remote command:
Pulse Delay - Pulse Generator
(External trigger only)
Sets the pulse delay. The pulse delay determines the time that elapses after a trigger
event before pulse modulation starts. The pulse delay is not effective for double pulse
generation.
Remote command:
Double Pulse Width - Pulse Generator
(Double Pulse only)
Sets the width of the second pulse.
Remote command:
[:SOURce<hw>]:PULM:DOUBle:WIDTh
Double Pulse Delay - Pulse Generator
(Double Pulse only)
Sets the delay from the start of the first pulse to the start of the second pulse.
Remote command:
[:SOURce<hw>]:PULM:DOUBle:DELay
Trigger Mode - Pulse Generator
Selects the trigger mode for pulse modulation.
Note:
An external trigger signal is supplied via the PULSE EXT connector.
"Auto"
The pulse generator signal is generated continuously.
RF Block