Remote Control Commands
R&S
®
SMBV100A
647
Operating Manual 1407.6062.32 ─ 08
Example:
IQ:OUTP:DIG:SRAT:MODE USER
with sample rate source User the internally generated clock ref-
erence signal is selected.
IQ:OUTP:DIG:SRAT 100 MHz
the sample rate for the output signal is set to 100 MHz.
Options:
B13 and B18
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe:SOURce
<Source>
This command selects the source for setting the sample rate of the digital I/Q output
signal.
Note:
With a connected R&S EX-IQ-Box either the internal clock source (User defined)
or an external clock (Digital I/Q In) can be selected in the settings dialog of the R&S EX-
IQ-Box. Therefore, the sample rate source is only indicated in this field.
Parameters:
<Source>
USER | DIN | DOUT | USER | DOUT
USER
The internally generated clock reference signal is used (option
R&S SMBV-B13). The sample rate is calculated and displayed in
the field "Value".
DOUT
An external clock reference signal is used. The clock signal is
directly fed in via pin CLK2 of the digital output interface (option
R&S SMBV-B18, Digital I/Q Out). The sample rate is displayed in
the field "Value".
*RST:
USER
Example:
IQ:OUTP:DIG:SRAT:SOUR USER
the internally generated clock reference signal is selected.
[:SOURce<hw>]:IQ:OUTPut:DIGital:STATe
<State>
This command switches on and off the digital I/Q output signals.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
IQ:OUTP:DIG:STAT ON
the digital I/Q output signals of path A are activated.
Options:
B13 and B18
7.14.11 SOURce:LFOutput Subsystem
This subsystem contains the commands for setting the LF signal source in CW and
Sweep mode as well as for analog modulation.
SOURce Subsystem
Summary of Contents for SMBV100A