Remote Control Commands
R&S
®
SMBV100A
646
Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP:MODE
<Mode>
This command activates
(USER
) or deactivates (DECimal) the user-defined step width
used when varying the level value with the level values
UP/DOWN
. The command is linked
to setting
Variation Active
for manual operation, i.e. the command also activates/deac-
tivates the user-defined step width used when varying the level value with the rotary knob.
Parameters:
<Mode>
DECimal | USER
*RST:
DECimal
Example:
IQ:OUTP:DIG:POW:STEP:MODE USER
actives the step width for level variation with the rotary knob (man-
ual operation) and with level values UP/DOWN (remote control).
Options:
B13 and B18
[:SOURce<hw>]:IQ:OUTPut:POWer:VIA
<Via>
This command activates the selected I/Q output level entry fields of the currently selected
signal path in the status bar.
Parameters:
<Via>
PEP | LEVel
PEP
The signal level is expressed in terms of a peak envelope power
value (PEP). The level entry fields and the corresponding units are
displayed in the status bar.
LEVel
The signal level is expressed in terms of a rms value. The level
entry field and the corresponding units are displayed in the status
bar.
*RST:
PEP
Example:
IQ:OUTP:POW:VIA PEP
the I/Q-signal level is set via PEP for the signal of path A.
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe
<SRate>
Using the sample rate source User the command sets the sample rate value of the output
signal. This command is not active for external clock sources
Parameters:
<SRate>
float
Range:
400 to 100 MHz
Increment: 0.01 Hz
*RST:
1E8
SOURce Subsystem
Summary of Contents for SMBV100A
Page 31: ......