![Rohde & Schwarz SMBV100A Manual Download Page 609](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_manual_1477734609.webp)
Remote Control Commands
R&S
®
SMBV100A
592
Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:BB:MCCW:CARRier:LIST:POWer
<Pow0[,Pow1..]>]
[:SOURce<hw>]:BB:MCCW:CARRier:LIST:POWer?
<Start>, <Count>
The command sets the power of the carrier with the aid of a value list. The first value in
the list is assigned to the carrier with index 0, the second value to the carrier with index
1, etc. The maximum length corresponds to the maximum number of multi carriers. There
is no need to enter all the values every time. Values not set by the value list are set with
the default values provided they have already been explicitly set by a previous command.
If this is the case, the values continue to apply until overwritten.
Setting parameters:
<Pow0[,Pow1..]>
float
Increment: 0.01
*RST:
0 dB
Query parameters:
<Start>
integer
Range:
0 to lastCarrier
<Count>
integer
Range:
1 to lastCarrier
Return values:
<Pow[,Pow..]>
float
Example:
BB:MCCW:CARR:LIST:POW -65 dB, -30 dB, -50
dB,...
sets the power of carrier 0 to -65 dB, carrier 1 to -30 dB and so on.
BB:MCCW:CARR:LIST:POW? 2,3
queries the power of carrier 1 and 2.
Response:
-30,-50
[:SOURce<hw>]:BB:MCCW:CARRier:LIST:STATe
<Stat0[,Stat1..]>]
[:SOURce<hw>]:BB:MCCW:CARRier:LIST:STATe?
<Start>, <Count>
The command switches the carrier on or off with the aid of a value list. The first value in
the list is assigned to the carrier with index 0, the second value to the carrier with index
1, etc. The maximum length corresponds to the maximum number of multi carriers. There
is no need to enter all the values every time. Values not set by the value list are set with
the default values provided they have already been explicitly set by a previous command.
If this is the case, the values continue to apply until overwritten.
Setting parameters:
<Stat0[,Stat1..]>
ON | OFF[,ON | OFF,...]
*RST:
ON
Query parameters:
<Start>
integer
Range:
0 to lastCarrier
<Count>
integer
Range:
1 to lastCarrier
SOURce Subsystem
Summary of Contents for SMBV100A
Page 31: ......