Remote Control Commands
R&S
®
SMBV100A
588
Operating Manual 1407.6062.32 ─ 08
Parameters:
<Q>
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
Default unit: PCT
Example:
BB:IMP:LEAK:Q 3 PCT
sets the leakage for the Q-component to 3 percent.
[:SOURce<hw>]:BB:IMPairment:OPTimization:MODE
<Mode>
This command sets the optimization mode.
Parameters:
<Mode>
FAST | QHIGh
FAST
Optimization is reached by compensation for I/Q skew.
QHIGh
Optimization is reached by compensation for I/Q skew and fre-
quency response correction.
*RST:
FAST
Example:
BB:IMP:OPT:MODE FAST
sets the optimization mode Fast.
[:SOURce<hw>]:BB:IMPairment:OPTimization:STATe
<State>
This command activates and deactivates internal compensation of signal distortions by
the I/Q modulator.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
OFF
Example:
BB:IMP:OPT:STAT ON
activates internal compensation of signal distortions.
[:SOURce<hw>]:BB:IMPairment:QUADrature[:ANGLe]
<Angle>
This command sets the quadrature offset for the digital I/Q signal.
Parameters:
<Angle>
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
Default unit: DEG
SOURce Subsystem