![Rohde & Schwarz SMBV100A Manual Download Page 581](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_manual_1477734581.webp)
Remote Control Commands
R&S
®
SMBV100A
564
Operating Manual 1407.6062.32 ─ 08
Parameters:
<Auto>
0 | 1 | OFF | ON
*RST:
1
Example:
BB:DM:FILT:OSAM:AUTO ON
The most sensible parameters are selected automatically.
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine[:ROLLoff]
<Cosine>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:GAUSs
<Gauss>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASs
<LPass>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASSEVM
<LPassEvm>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:PGAuss
<PGauss>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:RCOSine
<RCosine>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:SPHase
<SPhase>
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25
<Apco25>
The command sets the roll-off factor for filter type APCO25.
On selecting filter APCO25, the filter parameter is set to the default value.
Parameters:
<Apco25>
float
Range:
0.05 to 0.99
Increment: 0.01
*RST:
0.2
<Cosine>
float
Range:
0.05 to 1.0
Increment: 0.01
*RST:
0.35
<Gauss>
float
Range:
0.15 to 100000
Increment: 0.01
*RST:
0.3
<LPass>
float
Range:
0.05 to 2
Increment: 0.01
*RST:
0.5
<LPassEvm>
float
Range:
0.05 to 2
Increment: 0.01
*RST:
0.5
<PGauss>
float
Range:
0.15 to 2.5
Increment: 0.01
*RST:
0.3
SOURce Subsystem
Summary of Contents for SMBV100A
Page 31: ......