Page 2: ... 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners Throughout this manual products from Rohde Schwarz are indicated without the symbol e g R S RT ZF2 is indicated as R S RT ZF2 ...

Page 3: ...gnal quality test and development board indented to be used at laboratory or test and measurement areas These areas are used for analysis testing and servicing and where equipment is operated by trained personnel Operating site Only use the product indoors and keep it dry The product has no casing and is sensitive to moisture and humidity The product is suitable for pollution degree 2 environments...

Page 4: ... R S RTP K24 1800 6531 02 2 5 5GBASE T R S RTO K25 1333 0496 02 R S RTP K25 1337 8710 02 1000BASE T1 R S RTO K87 1337 8591 02 R S RTP K87 1800 6554 02 R S ScopeSuite software For data see the R S RT ZFxx Oscilloscope Test Fixtures Specifications at www rohde schwarz com brochure datasheet rto 2 1 Deliveries The R S RT ZF2 delivery package contains the following items R S RT ZF2 test boards Etherne...

Page 5: ...istortions R S RT ZF2C 1317 5639 02 2 2 Calibration Board The calibration board is required in return loss measurements It is used to cali brate the vector network analyzer for the measurement Calibration Board for RT ZF2 X100 X101 X102 Open Short Match Figure 2 1 Ethernet calibration board 2 3 Ethernet Test Board The Ethernet test board has several labeled sections designed for specific test case...

Page 6: ... Master A X705 B X704 C X702 D X703 X402 S501 S500 S502 S503 X403 X404 X406 X405 D C A B B A C D X503 X502 X504 X505 X500 X506 X501 X107 X305 X110 X108 X109 X111 Ethernet Test Fixture RT ZF2 R S X301 X303 X307 X300 X203 X206 X200 X201 X202 S200 S201 S204 S202 Load1 Load2 Loads 100R w o TPM TPM w o TPM TPM B A C D Ch C Ch D Ch A Ch B 1 2 3 4 5 6 7 Link Partner Figure 2 2 Ethernet test board 1 Twist...

Page 7: ...0BASE T test cases X203 X206 X200 Link Partner Left position Link partner is connected Right position Link partner is disconnected 3 Connecting the Board The appropriate DUT and probe connection depends on the test case The R S ScopeSuite software provides a step by step guide that shows the required setup for each test case The test preparation and measurements of the test cases are described in ...

Page 8: ...dth For precise power spectral density and power level measurements up to 1 GHz it is recommended to use an oscilloscope and a differential probe with 1 GHz bandwidth each Differential probe with at least 1GHz bandwidth R S RTO R S RTP K25 2 5 5GBASE T Ethernet compliance test option required option installed on the R S RTO R S RTP R S RT ZF2 Ethernet test fixture set 5GBASE T Ethernet compliance ...

Page 9: ...S RT ZF2 Ethernet test fixture set R S RT ZF3 frequency converter for transmitter distorsion tests 1000BASE T1 compliance tests R S RTO R S RTP oscilloscope with at least 2 GHz bandwidth Differential probe with 2 GHz bandwidth R S RTO R S RTP K87 100BASE T1 compliance test option required option installed on the R S RTO R S RTP R S RT ZF2 Ethernet test fixture set R S RT ZF6 frequency converter fo...