![Rohde & Schwarz R&S UPP User Manual Download Page 687](http://html.mh-extra.com/html/rohde-and-schwarz/rands-upp/rands-upp_user-manual_1477869687.webp)
Remote Control - Fundamentals
R&S
®
UPP
671
User Manual 1411.1055.32 ─ 10
Bit no.
Meaning
0
Measuring Ch2 (bit 1)
0 0
= Not used
0 1
= The information refers only to channel 2
1 0
= The information refers only to channel 1
1 1
= The information refers to both channels
3
Sweeping
This bit is set while the R&S
UPP is performing a sweep. Bits 8 and 9 indicate the sweep sta-
tus.
2
Not used
1
Not used
0
Not used
6.8.7
STATus:QUEStionable Register
This register contains information about questionable device statuses. These may
occur when the device is operated beyond its specifications. It can be read by the
queries
STATus:QUEStionable:CONDition?
or
STATus:QUEStionable[:EVENt]?
Reading the EVENt part deletes its content!
Bit no.
Meaning
15
Not used
14
Not used
13
Not used
12
11
10
Generator status
Bit 12, 11, 10
0 0 0 = Not used
0 0 1 = Generator Off
Both generator channels are off
0 1 0 = Generator Running
Generator outputs signal
0 1 1 = Not used
1 0 0 = Generator Halted
Generator outputs zero level
1 0 1 = Not used
1 1 0 = Generator Overload
Generator overloaded, output disabled
1 1 1 = Output Off
Output disabled
9
Not used
8
Not used
Status Reporting System
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...