![Rohde & Schwarz R&S UPP User Manual Download Page 506](http://html.mh-extra.com/html/rohde-and-schwarz/rands-upp/rands-upp_user-manual_1477869506.webp)
Instrument Functions
R&S
®
UPP
490
User Manual 1411.1055.32 ─ 10
COM Port
Selecting the COM port sets the RS232 parameter in such a way as to guarantee the
connection to the switcher without any further settings. The easy to handle setting
"Auto" is recommended.
After installing the USB driver or changing the COM port, the R&S
UPP must be restar-
ted.
"COM3 to
COM6"
Direct specification of the COM port occupied by a switcher. The call
setup to the switcher is done quickly. Note that the COM port number
may change if the switcher is connected to another USB port. There-
fore, the direct specification of the COM port is recommended only if
it is ensured that the wiring of the switcher does not change.
If the COM port that the switcher uses to communicate is to be
entered here, the port has to be determined after installation of the
USB driver by using the Windows Device Manager: Open Start, Set-
tings, Control Panel, System, Hardware, Device Manager, Ports
(COM&LPT) and right-click the USB to serial adapter entered there to
open its Properties. With Port setting, Advanced, you can determine
the interface to report it with this parameter field to the control soft-
ware of the R&S
UPP, or the COM interface listed in the Device Man-
ager is adjusted to the COM port selected in the R&S UPP.
"Auto"
All COM ports from 3 to 256 are searched for a connected switcher
and, if necessary, the connection is established. This search process
takes longer than the direct input of the COM port, but it generally
leads to immediate success without having to observe the COM port
number.
Remote command:
5.44.2
Default Setting
If the switcher is operated for the first time after loading the R&S
UPP default setup
(preset), the channels are set to a defined default state: All channels of the two
switcher types are set to "0", i.e. open. If additionally tracking is activated for the first
time, tracking "B vs A" is set to "-1" and tracking "Out vs Inp" is set to "0".
This ensures that when the user interface is opened all channels are open and thus
prohibited states in the test setup are avoided.
If you wish to obtain the same setting as in the default state manually, simply enter "All"
as the Tracking setting and set any channel to "0". All the others are then also adapted.
Switcher Panel
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...